[Home]  [Headlines]  [Latest Articles]  [Latest Comments]  [Post]  [Sign-in]  [Mail]  [Setup]  [Help] 

Status: Not Logged In; Sign In

Evidence Points to Voter Fraud in 2024 Wisconsin Senate Race

Rickards: Your Trump Investment Guide

Pentagon 'Shocked' By Houthi Arsenal, Sophistication Is 'Getting Scary'

Cancer Starves When You Eat These Surprising Foods | Dr. William Li

Megyn Kelly Gets Fiery About Trump's Choice of Matt Gaetz for Attorney General

Over 100 leftist groups organize coalition to rebuild morale and resist MAGA after Trump win

Mainstream Media Cries Foul Over Musk Meeting With Iran Ambassador...On Peace

Vaccine Stocks Slide Further After Trump Taps RFK Jr. To Lead HHS; CNN Outraged

Do Trump’s picks Rubio, Huckabee signal his approval of West Bank annexation?

Pac-Man

Barron Trump

Big Pharma-Sponsored Vaccinologist Finally Admits mRNA Shots Are Killing Millions

US fiscal year 2025 opens with a staggering $257 billion October deficit$3 trillion annual pace.

His brain has been damaged by American processed food.

Iran willing to resolve doubts about its atomic programme with IAEA

FBI Official Who Oversaw J6 Pipe Bomb Probe Lied About Receiving 'Corrupted' Evidence “We have complete data. Not complete, because there’s some data that was corrupted by one of the providers—not purposely by them, right,” former FBI official Steven D’Antuono told the House Judiciary Committee in a

Musk’s DOGE Takes To X To Crowdsource Talent: ‘80+ Hours Per Week,’

Female Bodybuilders vs. 16 Year Old Farmers

Whoopi Goldberg announces she is joining women in their sex abstinence

Musk secretly met with Iran's UN envoy NYT

D.O.G.E. To have a leaderboard of most wasteful government spending

In Most U.S. Cities, Social Security Payments Last Married Couples Just 19 Days Or Less

Another major healthcare provider files for Chapter 11 bankruptcy

The Ukrainians have put Tulsi Gabbard on their Myrotvorets kill list

Sen. Johnson unveils photo of Biden-appointed crossdressers after reporters rage over Gaetz nomination

sted on: Nov 15 07:56 'WE WOULD LOSE' War with Iran: Col. Lawrence Wilkerson

Israeli minister says Palestinians should have no voting or land rights

The Case For Radical Changes In US National Defense: Col. Douglas Macgregor

Biden's Regulations Legacy Costs Taxpayers $1.8 Trillion, 800 Times Larger than Trumps

Israeli Soldiers are BUSTED!


Science/Tech
See other Science/Tech Articles

Title: Analysis of Energy Requirements for the Expansion of the Dust Cloud Following the Collapse of 1 World Trade Center
Source: 911research.com
URL Source: http://www.911research.com/papers/dustvolume/volumev3.html
Published: Oct 16, 2003
Author: Jim Hoffman
Post Date: 2005-02-19 14:51:53 by RickyJ
Keywords: Requirements, Expansion, Following
Views: 56
Comments: 2

The North Tower's Dust Cloud

Analysis of Energy Requirements for the Expansion of the Dust Cloud Following the Collapse of 1 World Trade Center

by Jim Hoffman

October 16, 2003
[Version 3]

On September 11th, Both of the Twin Towers disintegrated into vast clouds of concrete and other materials, which blanketed Lower Manhattan. This paper shows that the energy required to produce the expansion of the dust cloud observed immediately following the collapse of 1 World Trade Center (the North Tower) was much greater than the gravitational energy available from its elevated mass. It uses only basic physics.

Introduction

Vast amounts of energy were released during the collapse of each of the Twin Towers in Lower Manhattan on September 11th, 2001. The accepted source of this energy was the gravitational potential energy of the towers, which was far greater than the energy released by the fires that preceded the collapses. The magnitude of that source cannot be determined with much precision thanks to the secrecy surrounding details of the towers' construction. However, FEMA's Building Performance Assessment Report gives an estimate: "Construction of WTC 1 resulted in the storage of more than 4 x 10^11 joules of potential energy over the 1,368-foot height of the structure." That is equal to about 111,000 KWH (kilowatt hours) per tower.

Of the many identifiable energy sinks in the collapses, one of the only ones that has been subjected to quantitative analysis is the thorough pulverization of the concrete in the towers. It is well documented that nearly all of the non-metallic constituents of the towers were pulverized into fine powder. The largest of these constituents by weight was the concrete that constituted the floor slabs of the towers. Jerry Russell estimated that the amount of energy required to crush concrete to 60 micron powder is about 1.5 KWH/ton. (See

http://www.911-strike.com/powder.htm.) That paper incorrectly assumes there were 600,000 tons of concrete in each tower, but Russell later provided a more accurate estimate of 90,000 tons of concrete per tower, based on FEMA's description of the towers' construction. That estimate implies the energy sink of concrete pulverization was on the order of 135,000 KWH per tower, which is already larger than the energy source of gravitational energy. However, the size of this sink is critically dependent on the fineness of the concrete powder, and on mechanical characteristics of the lightweight concrete thought to have been used in the towers. Available statistics about particle sizes of the dust, such as the study by Paul J. Lioy, et al., characterize particle sizes of aggregate dust samples, not of its constituents, such as concrete, fiberglass, hydrocarbon soot, etc. Based on diverse evidence, 60 microns would appear to be a high estimate for average concrete particle size, suggesting 135,000 KWH is a conservative estimate for the magnitude of the sink.

A second energy sink, that has apparently been overlooked, was many times the magnitude of the gravitational energy: the energy needed to expand the dust clouds to several times the volume of each tower within 30 seconds of the onset of their collapses. Note that the contents of the dust clouds had to come from building constituents -- gases and materials inside of or intrinsic to the building -- modulo any mixing with outside air. Given that the Twin Towers' dust clouds behaved like pyroclastic flows, with distinct boundaries and rapidly expanding frontiers (averaging perhaps 35 feet/second on the ground for the first 30 seconds), it is doubtful that mixing with ambient air accounted for a significant fraction of their volume. Therefore the dust clouds' expansion must have been primarily due to an expansion of building constituents. Possible sources of expansion include:

The evidence does not support the idea that chemical reactions in the dust cloud liberated vast quantities of gases. That leaves increases in gas temperatures and vaporization of solids and liquids, primarily water, to drive the expansion.

How much heat energy was involved in expanding the dust clouds? To calculate the energy we need to answer three questions:

  1. What was the volume of the dust clouds from a collapse at some time soon after it started (before the clouds began to diffuse)?
  2. How did the mixing of the dust cloud with ambient air contribute to its size, and how can this be factored out to obtain the volume occupied by gases and suspended materials originally inside the building?
  3. What is the ratio of that volume to the volume of the intact building?
  4. How much heat energy was required to produce that ratio of expansion?

Since I have better photographs for North Tower dust, I did the calculation for it.

1. Quantifying Dust Cloud Volume

To answer question 1, I made estimates based on photographs taken at approximately 30 seconds after the onset of the collapse. The photo in Figure 1 appears to have been taken around 30 seconds after the initiation of the collapse of the North Tower. The fact that the spire is visible directly behind Building 7 indicates the photo was not taken later than the 30 seconds, since video records show that the spire started to collapse at the around 29 seconds. In this photograph, as in other ones taken around that time, the dust clouds still have distinct boundaries.
Figure 1. Photograph from Chapter 5 of FEMA's Building Performance Assessment Report.

I used landmarks in this photo to make several approximate measurements of the frontier of the dust cloud. The following table lists some of them. Measurements are in feet. The first column lists heights above the street, and the second lists distances from the vertical axis of the North Tower.

labelheightdistancedescription
32301011west corner of 45 Park Place
5228 729top of south corner of building with stepped roof
6204 658east corner of Building 7, 30 stories below top
7600 776upwell towering over southeast end of Post Office
8700 ?upwell slightly higher than the top of Building 7
11190 870top of west corner of 22 Cortland St tower
12508 5888 stories below top of face of WFC 3
13498 5173 stories below top of upper face of WFC 2

To approximate the volume I used a cylinder, coaxial with the vertical axis of the North Tower, with a radius of 800 feet, and a height of 200 feet. All the above reference points lie outside of this volume. Although the cylinder does not lie entirely within the dust cloud, there are large parts of the cloud outside of it, such as the 700 foot high upwelling column south of Building 7. The cylinder has a volume of:

pi * (800 feet)^2 * 200 feet = 402,000,000 feet^3.
I subtract about a quarter for volume occupied by other buildings, giving 300,000,000 feet^3.

2. Factoring out Mixing and Diffusion

To accurately answer question 2 would require detailed knowledge of the fluid dynamics involved. However it does appear that for at least a minute, the dust cloud behaved as a separate fluid from the ambient air, maintaining a distinct boundary. There are several pieces of evidence that support this:

Initially the dust clouds must have been much heavier than air, given the mass of the concrete they carried and the distances they transported it. As time went on the cloud became more diffuse, but all of the photographs that can be verified as being within the first minute show opaque clouds with distinct boundaries, indicating the dominant mode of growth was expansion, not mixing or diffusion. It seems reasonable to assume that mixing with ambient air did not account for a significant fraction of the expansion in the volume of the dust cloud by 30 seconds of the start of the North Tower collapse. Nevertheless, I reduce the estimate of the dust cloud volume of building origin to 200,000,000 feet^3, imagining that a third of the growth may have been due to assimilation of ambient air.

3. Computing the Expansion Ratio

The answer to question 3 is easy. The volume of a tower, with it's 207 foot width and 1368 foot height, is:

1368 feet * 207 feet * 207 feet = 58,617,432 feet^3.

So the ratio of the expanded gasses and suspended materials from the tower to the original volume of the tower is:

200,000,000 feet^3 / 58,617,432 feet^3 = 3.41.

4. Computing the Required Heat Input

Above I identified two energy sinks that could have driven expansion of the dust cloud: thermodynamic expansion of gases, and vaporization of liquids and solids. Since most constituents and contents of the building other than water would require very high temperatures to vaporize, I consider only the vaporization of water in evaluating the second sink.

It is clearly not possible to determine with any precision the relative contributions of these two sinks to the expansion of the dust cloud. If the cloud remained uniform in temperature and density for the first 30 seconds, then the expansion would consist of three distinct phases:

Since such uniform conditions were not present, I will first treat the two energy sinks separately, and will compute the energy requirements for each if it alone were responsible for the expansion.

4.1. The Thermodynamic Expansion Sink

The ideal gas law can be used to compute a lower bound for the amount of heat energy required to induce the observed expansion of the dust cloud, assuming that the expansion was entirely due to thermodynamic expansion. That law states that the product of the volume and pressure of a parcel of a gas is proportional to absolute temperature. It is written PV = nRT, where:

P = pressure

V = volume T = absolute temperature n = molar quantity R = constant

Absolute temperature is expressed in Kelvin (K), which is Celsius + 273. Applied to the tower collapse, the equation holds that the ratio of volumes of gasses from the building before and after expansion is roughly equal to the ratio of temperatures of the gasses before and after heating. That allows us to compute the minimum energy needed to achieve a given expansion ratio knowing only the thermal mass of the gasses and their average temperature before the collapse.

I say that the ideal gas law allows the computation of only the lower bound of the required energy input due to the following four factors.

(1 image)

Post Comment   Private Reply   Ignore Thread  


TopPage UpFull ThreadPage DownBottom/Latest

#1. To: RickyJ (#0)

Thermodynamics bump.

randge  posted on  2005-02-19   15:05:45 ET  Reply   Trace   Private Reply  


#2. To: RickyJ (#0)

Uh - OK

I don't buy fedgov's story either.

Lod  posted on  2005-02-19   15:59:44 ET  Reply   Trace   Private Reply  


TopPage UpFull ThreadPage DownBottom/Latest